<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	 xmlns:media="http://search.yahoo.com/mrss/" >

<channel>
	<title>Industrial Reverse Osmosis Membranes &#8211; Complete Water Solutions</title>
	<atom:link href="https://complete-water.com/product-category/ro-membranes/feed" rel="self" type="application/rss+xml" />
	<link>https://complete-water.com</link>
	<description>Full Service Solutions For Industrial and Commercial Water Treatment Needs</description>
	<lastBuildDate>Fri, 13 Jun 2025 16:38:31 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.8.1</generator>

<image>
	<url>https://complete-water.com/wp-content/uploads/cropped-Complete-Water-32x32.png</url>
	<title>Industrial Reverse Osmosis Membranes &#8211; Complete Water Solutions</title>
	<link>https://complete-water.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Toray RO Membranes &#124; TM-Sea Water &#124; TSW-440LE</title>
		<link>https://complete-water.com/product/toray-ro-membranes-tm-sea-water-tsw-440le</link>
		
		<dc:creator><![CDATA[Melissa Pitner]]></dc:creator>
		<pubDate>Fri, 13 Jun 2025 16:01:36 +0000</pubDate>
				<guid isPermaLink="false">https://complete-water.com/?post_type=product&#038;p=35632</guid>

					<description><![CDATA[TSW-LE Series Super Low-Energy Sea Water Reverse Osmosis (RO) Membrane Element Toray manufactures seawater RO membranes in 4, 8, and 16-inch diameters that can treat seawater or high salinity water sources with &#62; 10,000 ppm. Our products are widely used for mega desalination plants, watermakers for private boats and commercial ships, and treating mining tailing [&#8230;]]]></description>
										<content:encoded><![CDATA[<h2>TSW-LE Series</h2>
<h3>Super Low-Energy Sea Water Reverse Osmosis (RO) Membrane Element</h3>
<p>Toray manufactures seawater RO membranes in 4, 8, and 16-inch diameters that can treat seawater or high salinity water sources with &gt; 10,000 ppm. Our products are widely used for mega desalination plants, watermakers for private boats and commercial ships, and treating mining tailing water for reuse or discharge.</p>
<p>Toray&#8217;s reverse osmosis membrane technology applies decades of R&amp;D and precision automated manufacturing under ISO 9001 for consistency in product quality. State-of-the-art cross-linked fully aromatic polyamide composite membranes produce high-quality permeate and robust membrane chemistry for improved performance and longer membrane life.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Veolia RO Membranes &#124; DK 400 Series &#124; DK-440</title>
		<link>https://complete-water.com/product/dk-440</link>
		
		<dc:creator><![CDATA[Melissa Pitner]]></dc:creator>
		<pubDate>Thu, 24 Oct 2024 20:22:47 +0000</pubDate>
				<guid isPermaLink="false">https://complete-water.com/?post_type=product&#038;p=32789</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div  class="vc_row wpb_row ">
	<div class="wpb_column vc_column_container vc_col-sm-12 "><div class="vc_column-inner " >
		<div class="wpb_wrapper">
			
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>The D-Series family of proprietary thin-film nanofiltration membrane elements is characterized by an approximate molecular weight cut-off of 150-300 Dalton for uncharged organic molecules. Divalent and multivalent anions are preferentially rejected by the membrane while monovalent ion rejection is dependent upon feed concentration and composition. Since monovalent ions pass through the membrane, they do not contribute to the osmotic pressure, thus enabling D-Series nanofiltration membrane systems to operate at feed pressures below those of RO systems.</p>
<p>Among other applications, DK High Rejection NF Elements are used for dye brine purification, demineralization / concentration of organic solutions and metals recovery.</p>
<p><strong>Typical Operating Flux:</strong> 5-20 GFD (8-34 LMH)<br />
<strong>Maximum Operating Pressure:</strong></p>
<p>600psi (4,137kPa) if T&lt;95°F (35°C)<br />
435psi (3,000kPa) if T&gt;95°F (35°C)<br />
<strong>Maximum Temperature:</strong></p>
<p>Continuous Operation: 122°F (50°C)<br />
Clean-In-Place (CIP): 122°F (50°C)<br />
<strong>pH Range:</strong></p>
<p>Continuous Operation: 3.0 – 9.0<br />
Clean-In-Place (CIP): 2.0 -11.0<br />
<strong>Maximum Pressure Drop:</strong></p>
<p>Over an element: 15 psi (103 kPa)<br />
Per housing: 60 psi (414 kPa)<br />
<strong>Chlorine Tolerance:</strong> 500 ppm hours, dechlorination recommended</p>
<p><strong>Feed water:</strong> NTU &lt; 1 SDI₁₅ &lt; 5</p>

		</div>
	</div>

		</div> </div>
	</div> 
</div>
</div>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Veolia RO Membranes &#124; DK 400 Series &#124; DK-400</title>
		<link>https://complete-water.com/product/dk-400</link>
		
		<dc:creator><![CDATA[Melissa Pitner]]></dc:creator>
		<pubDate>Thu, 24 Oct 2024 19:37:18 +0000</pubDate>
				<guid isPermaLink="false">https://complete-water.com/?post_type=product&#038;p=32786</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div  class="vc_row wpb_row ">
	<div class="wpb_column vc_column_container vc_col-sm-12 "><div class="vc_column-inner " >
		<div class="wpb_wrapper">
			
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>The D-Series family of proprietary thin-film nanofiltration membrane elements is characterized by an approximate molecular weight cut-off of 150-300 Dalton for uncharged organic molecules. Divalent and multivalent anions are preferentially rejected by the membrane while monovalent ion rejection is dependent upon feed concentration and composition. Since monovalent ions pass through the membrane, they do not contribute to the osmotic pressure, thus enabling D-Series nanofiltration membrane systems to operate at feed pressures below those of RO systems.</p>
<p>Among other applications, DK High Rejection NF Elements are used for dye brine purification, demineralization / concentration of organic solutions and metals recovery.</p>
<p><strong>Typical Operating Flux:</strong> 5-20 GFD (8-34 LMH)<br />
<strong>Maximum Operating Pressure:</strong></p>
<p>600psi (4,137kPa) if T&lt;95°F (35°C)<br />
435psi (3,000kPa) if T&gt;95°F (35°C)<br />
<strong>Maximum Temperature:</strong></p>
<p>Continuous Operation: 122°F (50°C)<br />
Clean-In-Place (CIP): 122°F (50°C)<br />
<strong>pH Range:</strong></p>
<p>Continuous Operation: 3.0 – 9.0<br />
Clean-In-Place (CIP): 2.0 -11.0<br />
<strong>Maximum Pressure Drop:</strong></p>
<p>Over an element: 15 psi (103 kPa)<br />
Per housing: 60 psi (414 kPa)<br />
<strong>Chlorine Tolerance:</strong> 500 ppm hours, dechlorination recommended</p>
<p><strong>Feed water:</strong> NTU &lt; 1 SDI₁₅ &lt; 5</p>

		</div>
	</div>

		</div> </div>
	</div> 
</div>
</div>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Veolia RO Membranes &#124; GK Series &#124; GK4040C50</title>
		<link>https://complete-water.com/product/gk4040c50</link>
		
		<dc:creator><![CDATA[Melissa Pitner]]></dc:creator>
		<pubDate>Thu, 24 Oct 2024 18:05:04 +0000</pubDate>
				<guid isPermaLink="false">https://complete-water.com/?post_type=product&#038;p=32779</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div  class="vc_row wpb_row ">
	<div class="wpb_column vc_column_container vc_col-sm-12 "><div class="vc_column-inner " >
		<div class="wpb_wrapper">
			
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>The GK Series ultrafiltration (UF) spiral wound membranes are characterized by a molecular weight cutoff (MWCO) of 3,500 on polyethylene glycol (PEG) and a smooth, fouling resistant membrane surface.</p>
<p>GK spiral wound membranes are used for surface water pretreatment, color, or total organic carbon (TOC) reduction, and chemical purification.</p>
<p><strong>Typical Operating Flux:</strong> 5-20 GFD (8-34 LMH)<br />
<strong>Maximum Operating Pressure:</strong> 400 psi (2,760 kPa)<br />
<strong>Maximum Temperature:</strong></p>
<p>Continuous Operation: 122°F (50°C)<br />
Clean-In-Place (CIP): 122°F (50°C)<br />
<strong>pH Range:</strong></p>
<p>Continuous Operation: 2.0-10.0<br />
Clean-In-Place (CIP): 1.0-13.0 (3)<br />
<strong>Maximum Pressure Drop:</strong></p>
<p>Over an element: 15 psi (103 kPa)<br />
Per housing: 60 psi (414 kPa)<br />
<strong>Chlorine Tolerance:</strong> 20-50 ppm days</p>

		</div>
	</div>

		</div> </div>
	</div> 
</div>
</div>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Veolia RO Membranes &#124; GK Series &#124; GK8040C30</title>
		<link>https://complete-water.com/product/gk8040c30</link>
		
		<dc:creator><![CDATA[Melissa Pitner]]></dc:creator>
		<pubDate>Thu, 24 Oct 2024 17:25:16 +0000</pubDate>
				<guid isPermaLink="false">https://complete-water.com/?post_type=product&#038;p=32776</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div  class="vc_row wpb_row ">
	<div class="wpb_column vc_column_container vc_col-sm-12 "><div class="vc_column-inner " >
		<div class="wpb_wrapper">
			
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>The GK Series ultrafiltration (UF) spiral wound membranes are characterized by a molecular weight cutoff (MWCO) of 3,500 on polyethylene glycol (PEG) and a smooth, fouling resistant membrane surface.</p>
<p>GK spiral wound membranes are used for surface water pretreatment, color, or total organic carbon (TOC) reduction, and chemical purification.</p>
<p><strong>Typical Operating Flux:</strong> 5-20 GFD (8-34 LMH)<br />
<strong>Maximum Operating Pressure:</strong> 400 psi (2,760 kPa)<br />
<strong>Maximum Temperature:</strong></p>
<p>Continuous Operation: 122°F (50°C)<br />
Clean-In-Place (CIP): 122°F (50°C)<br />
<strong>pH Range:</strong></p>
<p>Continuous Operation: 2.0-10.0<br />
Clean-In-Place (CIP): 1.0-13.0 (3)<br />
<strong>Maximum Pressure Drop:</strong></p>
<p>Over an element: 15 psi (103 kPa)<br />
Per housing: 60 psi (414 kPa)<br />
<strong>Chlorine Tolerance:</strong> 20-50 ppm days</p>

		</div>
	</div>

		</div> </div>
	</div> 
</div>
</div>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Veolia RO Membranes &#124; RL Series &#124; RL8040F-400</title>
		<link>https://complete-water.com/product/rl8040f-400</link>
		
		<dc:creator><![CDATA[Melissa Pitner]]></dc:creator>
		<pubDate>Thu, 24 Oct 2024 16:09:11 +0000</pubDate>
				<guid isPermaLink="false">https://complete-water.com/?post_type=product&#038;p=32772</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div  class="vc_row wpb_row ">
	<div class="wpb_column vc_column_container vc_col-sm-12 "><div class="vc_column-inner " >
		<div class="wpb_wrapper">
			
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>The RL Series nanofiltration elements are made with a proprietary thin-film membrane characterized by high flux and high rejection of sulfate salts, hardness, heavy metals, and recalcitrant organic compounds contributing to chemical oxygen demand (COD). The RL membrane has an approximate molecular weight cut-off of 200-400 Dalton for uncharged organic molecules.</p>
<p>RL Series elements are typically applied to remove and concentrate sulfate salts, hardness, and hard-to-degrade COD from industrial wastewater or effluent, such as cooling tower blowdown, reverse osmosis reject, landfill leachate, secondary and tertiary effluent. The COD and the concentration ratio of divalent and multi-valent salts to monovalent salts would reduce significantly in the permeate stream, thereby enabling its beneficial reuse and waste reduction.</p>
<p><strong>Typical Operating Pressure:</strong> 60-300 psi (414-2,069 kPa)<br />
<strong>Typical Operating Flux:</strong> 10-20 GFD (15-35 LMH)<br />
<strong>Maximum Operating Pressure:</strong> 600 psi (4,137 kPa)<br />
<strong>Maximum Temperature:</strong></p>
<p>Continuous operation: 122°F (50°C)<br />
Clean-In-Place (CIP): 122°F (50°C)<br />
<strong>pH Range: </strong></p>
<p>Optimum rejection: 6.0-7.0,<br />
Continuous operation: 3.0-9.0,<br />
Clean-In-Place (CIP): 2.0-11.0<br />
<strong>Maximum Pressure Drop:</strong></p>
<p>Over an element: 15 psi (103 kPa)<br />
Per housing: 50 psi (345 kPa)<br />
<strong>Chlorine Tolerance:</strong> 1,000+ ppm-hours, Dechlorination recommended<br />
<strong>Feedwater:</strong> NTU &lt; 1 SDI &lt; 3</p>

		</div>
	</div>

		</div> </div>
	</div> 
</div>
</div>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Veolia RO Membranes &#124; RL Series &#124; RL4040FM</title>
		<link>https://complete-water.com/product/rl4040fm</link>
		
		<dc:creator><![CDATA[Melissa Pitner]]></dc:creator>
		<pubDate>Thu, 24 Oct 2024 15:46:12 +0000</pubDate>
				<guid isPermaLink="false">https://complete-water.com/?post_type=product&#038;p=32769</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div  class="vc_row wpb_row ">
	<div class="wpb_column vc_column_container vc_col-sm-12 "><div class="vc_column-inner " >
		<div class="wpb_wrapper">
			
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>The RL Series nanofiltration elements are made with a proprietary thin-film membrane characterized by high flux and high rejection of sulfate salts, hardness, heavy metals, and recalcitrant organic compounds contributing to chemical oxygen demand (COD). The RL membrane has an approximate molecular weight cut-off of 200-400 Dalton for uncharged organic molecules.</p>
<p>RL Series elements are typically applied to remove and concentrate sulfate salts, hardness, and hard-to-degrade COD from industrial wastewater or effluent, such as cooling tower blowdown, reverse osmosis reject, landfill leachate, secondary and tertiary effluent. The COD and the concentration ratio of divalent and multi-valent salts to monovalent salts would reduce significantly in the permeate stream, thereby enabling its beneficial reuse and waste reduction.</p>
<p><strong>Typical Operating Pressure:</strong> 60-300 psi (414-2,069 kPa)<br />
<strong>Typical Operating Flux:</strong> 10-20 GFD (15-35 LMH)<br />
<strong>Maximum Operating Pressure:</strong> 600 psi (4,137 kPa)<br />
<strong>Maximum Temperature:</strong></p>
<p>Continuous operation: 122°F (50°C)<br />
Clean-In-Place (CIP): 122°F (50°C)<br />
<strong>pH Range: </strong></p>
<p>Optimum rejection: 6.0-7.0,<br />
Continuous operation: 3.0-9.0,<br />
Clean-In-Place (CIP): 2.0-11.0<br />
<strong>Maximum Pressure Drop:</strong></p>
<p>Over an element: 15 psi (103 kPa)<br />
Per housing: 50 psi (345 kPa)<br />
<strong>Chlorine Tolerance:</strong> 1,000+ ppm-hours, Dechlorination recommended<br />
<strong>Feedwater:</strong> NTU &lt; 1 SDI &lt; 3</p>

		</div>
	</div>

		</div> </div>
	</div> 
</div>
</div>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Veolia RO Membranes &#124; OSMO USPG Series &#124; 817-USPG</title>
		<link>https://complete-water.com/product/osmo-817-uspg</link>
		
		<dc:creator><![CDATA[Melissa Pitner]]></dc:creator>
		<pubDate>Thu, 24 Oct 2024 14:26:09 +0000</pubDate>
				<guid isPermaLink="false">https://complete-water.com/?post_type=product&#038;p=32768</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div  class="vc_row wpb_row ">
	<div class="wpb_column vc_column_container vc_col-sm-12 "><div class="vc_column-inner " >
		<div class="wpb_wrapper">
			
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>The OSMO USPG series has been designed for pharmaceutical applications with a sanitary Full-Fit design. The elements feature a 316 SS electropolished central tube and Noryl ATDs.</p>
<p>The OSMO USPG Elements are typically used in pharmaceutical related processes requiring regulations. All materials used in the OSMO USPG Series have passed testing according to USP Class VI-121°C. Each element is shipped with a certificate of compliance.</p>
<p><strong>Typical Operating Pressure:</strong> 200 psi (1,379 kPa)<br />
<strong>Typical Operating Flux:</strong> 10 – 20 GFD (15 – 35 LMH)<br />
<strong>Maximum Operating Pressure:</strong> 600 psi (4,137 kPa)<br />
<strong>Maximum Temperature:</strong></p>
<p>Continuous operation: 122°F (50°C)<br />
Clean-In-Place (CIP): 122°F (50°C)<br />
<strong>pH Range: </strong></p>
<p>Optimum rejection: 7.0-7.5,<br />
Continuous operation: 4.0-11.0,<br />
Clean-In-Place (CIP): 2.0-11.5<br />
<strong>Maximum Pressure Drop:</strong></p>
<p>Over an element: 10 psi (69 kPa)<br />
Per housing: 50 psi (345 kPa)<br />
<strong>Chlorine Tolerance:</strong> 1,000+ ppm-hours, Dechlorination recommended<br />
<strong>Feedwater:</strong> NTU &lt; 1 SDI &lt; 3</p>

		</div>
	</div>

		</div> </div>
	</div> 
</div>
</div>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Veolia RO Membranes &#124; OSMO USPG Series &#124; 813-USPG</title>
		<link>https://complete-water.com/product/osmo-813-uspg</link>
		
		<dc:creator><![CDATA[Melissa Pitner]]></dc:creator>
		<pubDate>Thu, 24 Oct 2024 14:16:07 +0000</pubDate>
				<guid isPermaLink="false">https://complete-water.com/?post_type=product&#038;p=32767</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div  class="vc_row wpb_row ">
	<div class="wpb_column vc_column_container vc_col-sm-12 "><div class="vc_column-inner " >
		<div class="wpb_wrapper">
			
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>The OSMO USPG series has been designed for pharmaceutical applications with a sanitary Full-Fit design. The elements feature a 316 SS electropolished central tube and Noryl ATDs.</p>
<p>The OSMO USPG Elements are typically used in pharmaceutical related processes requiring regulations. All materials used in the OSMO USPG Series have passed testing according to USP Class VI-121°C. Each element is shipped with a certificate of compliance.</p>
<p><strong>Typical Operating Pressure:</strong> 200 psi (1,379 kPa)<br />
<strong>Typical Operating Flux:</strong> 10 – 20 GFD (15 – 35 LMH)<br />
<strong>Maximum Operating Pressure:</strong> 600 psi (4,137 kPa)<br />
<strong>Maximum Temperature:</strong></p>
<p>Continuous operation: 122°F (50°C)<br />
Clean-In-Place (CIP): 122°F (50°C)<br />
<strong>pH Range: </strong></p>
<p>Optimum rejection: 7.0-7.5,<br />
Continuous operation: 4.0-11.0,<br />
Clean-In-Place (CIP): 2.0-11.5<br />
<strong>Maximum Pressure Drop:</strong></p>
<p>Over an element: 10 psi (69 kPa)<br />
Per housing: 50 psi (345 kPa)<br />
<strong>Chlorine Tolerance:</strong> 1,000+ ppm-hours, Dechlorination recommended<br />
<strong>Feedwater:</strong> NTU &lt; 1 SDI &lt; 3</p>

		</div>
	</div>

		</div> </div>
	</div> 
</div>
</div>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Veolia RO Membranes &#124; OSMO USPG Series &#124; 416-USPG</title>
		<link>https://complete-water.com/product/osmo-416-uspg</link>
		
		<dc:creator><![CDATA[Melissa Pitner]]></dc:creator>
		<pubDate>Thu, 24 Oct 2024 13:34:36 +0000</pubDate>
				<guid isPermaLink="false">https://complete-water.com/?post_type=product&#038;p=32764</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div  class="vc_row wpb_row ">
	<div class="wpb_column vc_column_container vc_col-sm-12 "><div class="vc_column-inner " >
		<div class="wpb_wrapper">
			
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>The OSMO USPG series has been designed for pharmaceutical applications with a sanitary Full-Fit design. The elements feature a 316 SS electropolished central tube and Noryl ATDs.</p>
<p>The OSMO USPG Elements are typically used in pharmaceutical related processes requiring regulations. All materials used in the OSMO USPG Series have passed testing according to USP Class VI-121°C. Each element is shipped with a certificate of compliance.</p>
<p><strong>Typical Operating Pressure:</strong> 200 psi (1,379 kPa)<br />
<strong>Typical Operating Flux:</strong> 10 – 20 GFD (15 – 35 LMH)<br />
<strong>Maximum Operating Pressure:</strong> 600 psi (4,137 kPa)<br />
<strong>Maximum Temperature:</strong></p>
<p>Continuous operation: 122°F (50°C)<br />
Clean-In-Place (CIP): 122°F (50°C)<br />
<strong>pH Range: </strong></p>
<p>Optimum rejection: 7.0-7.5,<br />
Continuous operation: 4.0-11.0,<br />
Clean-In-Place (CIP): 2.0-11.5<br />
<strong>Maximum Pressure Drop:</strong></p>
<p>Over an element: 10 psi (69 kPa)<br />
Per housing: 50 psi (345 kPa)<br />
<strong>Chlorine Tolerance:</strong> 1,000+ ppm-hours, Dechlorination recommended<br />
<strong>Feedwater:</strong> NTU &lt; 1 SDI &lt; 3</p>

		</div>
	</div>

		</div> </div>
	</div> 
</div>
</div>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Veolia RO Membranes &#124; INDUSTRIAL NF1 &#124; 8040F35</title>
		<link>https://complete-water.com/product/industrial-nf1-8040f35</link>
		
		<dc:creator><![CDATA[Melissa Pitner]]></dc:creator>
		<pubDate>Wed, 23 Oct 2024 20:07:30 +0000</pubDate>
				<guid isPermaLink="false">https://complete-water.com/?post_type=product&#038;p=32757</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div  class="vc_row wpb_row ">
	<div class="wpb_column vc_column_container vc_col-sm-12 "><div class="vc_column-inner " >
		<div class="wpb_wrapper">
			
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>The Industrial NF1 nanofiltration elements feature a D-Series proprietary thin-film membrane to remove low solubility salts and organics from concentrated effluents and brines.</p>
<p>The Industrial NF1 will permeate sodium chloride NaCl and reject the sodium sulfate Na2SO4. The Industrial NF1 elements are high pressure elements that can operate up to 80 bar. This salt segregation combined with a high-pressure construction enables production of a pure highly concentrated (&gt; 150 g/L) single salt. The thermal process for Zero Liquid Discharge or Minimum Liquid Discharge projects can greatly be simplified to a crystallizer only, strongly reducing the investment and the operational costs.</p>
<p><strong>Typical Operating Pressure:</strong> 5 &#8211; 20 GFD (8 – 34 LMH)<br />
<strong>Maximum Operating Pressure:</strong></p>
<p>&lt; 77°F (25°C) 1,200psi (8,253kPa)<br />
&lt; 86°F (30°C) 1,000psi (6,895kPa)<br />
&lt; 95°F (35°C) 850psi (5,860kPa)<br />
&lt; 104°F (40°C) 750psi (5,171kPa)<br />
&lt; 113°F (45°C) 670psi (4,619Pa)<br />
&lt; 122°F (50°C) 600psi (4,137kPa)<br />
<strong>Maximum Temperature:</strong></p>
<p>Continuous operation: 122°F (50°C)<br />
Clean-In-Place (CIP): 122°F (50°C)<br />
<strong>pH Range:</strong></p>
<p>Continuous operation: 3.0 – 9.0<br />
Clean-In-Place (CIP): 2.0 – 11.0<br />
<strong>Maximum Pressure Drop:</strong></p>
<p>Over an element: 15psi (103kPa)<br />
Per housing: 60psi (414kPa)<br />
<strong>Chlorine Tolerance: </strong>500 ppm x hours, dechlorination recommended<br />
<strong>Feedwater:</strong> NTU &lt; 1 SDI15 &lt; 5</p>

		</div>
	</div>

		</div> </div>
	</div> 
</div>
</div>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Veolia RO Membranes &#124; INDUSTRIAL NF1 &#124; 4040F35</title>
		<link>https://complete-water.com/product/industrial-nf1-4040f35</link>
		
		<dc:creator><![CDATA[Melissa Pitner]]></dc:creator>
		<pubDate>Wed, 23 Oct 2024 19:24:45 +0000</pubDate>
				<guid isPermaLink="false">https://complete-water.com/?post_type=product&#038;p=32753</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div  class="vc_row wpb_row ">
	<div class="wpb_column vc_column_container vc_col-sm-12 "><div class="vc_column-inner " >
		<div class="wpb_wrapper">
			
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>The Industrial NF1 nanofiltration elements feature a D-Series proprietary thin-film membrane to remove low solubility salts and organics from concentrated effluents and brines.</p>
<p>The Industrial NF1 will permeate sodium chloride NaCl and reject the sodium sulfate Na2SO4. The Industrial NF1 elements are high pressure elements that can operate up to 80 bar. This salt segregation combined with a high-pressure construction enables production of a pure highly concentrated (&gt; 150 g/L) single salt. The thermal process for Zero Liquid Discharge or Minimum Liquid Discharge projects can greatly be simplified to a crystallizer only, strongly reducing the investment and the operational costs.</p>
<p><strong>Typical Operating Pressure:</strong> 5 &#8211; 20 GFD (8 – 34 LMH)<br />
<strong>Maximum Operating Pressure:</strong></p>
<p>&lt; 77°F (25°C) 1,200psi (8,253kPa)<br />
&lt; 86°F (30°C) 1,000psi (6,895kPa)<br />
&lt; 95°F (35°C) 850psi (5,860kPa)<br />
&lt; 104°F (40°C) 750psi (5,171kPa)<br />
&lt; 113°F (45°C) 670psi (4,619Pa)<br />
&lt; 122°F (50°C) 600psi (4,137kPa)<br />
<strong>Maximum Temperature:</strong></p>
<p>Continuous operation: 122°F (50°C)<br />
Clean-In-Place (CIP): 122°F (50°C)<br />
<strong>pH Range:</strong></p>
<p>Continuous operation: 3.0 – 9.0<br />
Clean-In-Place (CIP): 2.0 – 11.0<br />
<strong>Maximum Pressure Drop:</strong></p>
<p>Over an element: 15psi (103kPa)<br />
Per housing: 60psi (414kPa)<br />
<strong>Chlorine Tolerance: </strong>500 ppm x hours, dechlorination recommended<br />
<strong>Feedwater:</strong> NTU &lt; 1 SDI15 &lt; 5</p>

		</div>
	</div>

		</div> </div>
	</div> 
</div>
</div>]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
